Oil resistant Cylindrical Proximity Sensor (Automotive) E2E Designed and tested for Automotive assembly lines * tested oil resistance on commonly used lubricants in Automotive industry Ordering Information DC 2-wire/Pre-wired Models - enhanced oil resistant PUR/PE cable Self-diagnostic output function No Size Sensing distance Model NO Shielded NC M8 2 mm E2E-X2D1-U E2E-X2D2-U M12 3 mm E2E-X3D1-U E2E-X3D2-U M18 7 mm E2E-X7D1-U E2E-X7D2-U M30 10 mm E2E-X10D1-U E2E-X10D2-U DC 2-wire/Pigtail-connector - enhanced oil resistant PUR/PE cable Self-diagnostic output function No Size Sensing distance Model NO Shielded NC M8 2 mm E2E-X2D1-M1TGJ-U 0.3 M E2E-X2D2-M1TGJ-U 0.3 M M12 3 mm E2E-X3D1-M1TGJ-U 0.3 M E2E-X3D2-M1TGJ-U 0.3 M M18 7 mm E2E-X7D1-M1TGJ-U 0.3 M E2E-X7D2-M1TGJ-U 0.3 M M30 10 mm E2E-X10D1-M1TGJ-U 0.3 M E2E-X10D2-M1TGJ-U 0.3 M DC 2-wire/Pre-wired Models - PVC cable Self-diagnostic output function Yes Size Model NO Shielded Unshielded No Sensing distance Shielded Unshielded NC M12 3 mm E2E-X3D1S (See note 1.) --- M18 7 mm E2E-X7D1S (See note 1.) --- M30 10 mm E2E-X10D1S (See note 1.) --- M12 8 mm E2E-X8MD1S (See note 1.) --- M18 14 mm E2E-X14MD1S (See note 1.) --- M30 20 mm E2E-X20MD1S (See note 1.) --- M8 2 mm E2E-X2D1-N (See notes 2 and 3.) E2E-X2D2-N (See note 3.) M12 3 mm E2E-X3D1-N (See notes 1, 2 and 3.) E2E-X3D2-N (See note 3.) M18 7 mm E2E-X7D1-N (See notes 1, 2 and 3.) E2E-X7D2-N (See note 3.) M30 10 mm E2E-X10D1-N (See notes 1, 2 and 3.) E2E-X10D2-N M8 4 mm E2E-X4MD1 (See notes 2 and 3.) M12 8 mm E2E-X8MD1 (See notes 1, 2 and 3.) E2E-X8MD2 M18 14 mm E2E-X14MD1 (See notes 1, 2 and 3.) E2E-X14MD2 M30 20 mm E2E-X20MD1 (See notes 1, 2 and 3. E2E-X20MD2 E2E-X4MD2 *1. In addition to the above models, E2E-X@@15 models (e.g., E2E-X3D15-N), which are different in frequency from the above models, are available. *2. E2E models with a robotics cable are available as well. The model number of a model with a robotics cable has the suffix "-R" (e.g., E2E-X3D1-R). *3. Cables with a length of 5 m are also available. Specify the cable length at the end of the model number (e.g., E2E-X3D1-N 5M). E2E 1 DC 2-wire/Connector Models Connector Self-diagnostic output function M12 Yes Size Shielded Unshielded No Shielded Unshielded M8 Shielded Sensing distance M12 3 mm Model NO NC E2E-X3D1S-M1 --- M18 7 mm E2E-X7D1S-M1 --- M30 10 mm E2E-X10D1S-M1 --- M12 8 mm E2E-X8MD1S-M1 --- M18 14 mm E2E-X14MD1S-M1 --- M30 20 mm E2E-X20MD1S-M1 --- M8 2 mm E2E-X2D1-M1G E2E-X2D2-M1G M12 3 mm E2E-X3D1-M1G (See note.) E2E-X3D2-M1G M18 7 mm E2E-X7D1-M1G (See note.) E2E-X7D2-M1G M30 10 mm E2E-X10D1-M1G (See note.) E2E-X10D2-M1G M8 4 mm E2E-X4MD1-M1G E2E-X4MD2-M1G M12 8 mm E2E-X8MD1-M1G (See note.) E2E-X8MD2-M1G M18 14 mm E2E-X14MD1-M1G (See note.) E2E-X14MD2-M1G M30 20 mm E2E-X20MD1-M1G (See note.) E2E-X20MD2-M1G M8 2 mm E2E-X2D1-M3G E2E-X2D2-M3G 4 mm E2E-X4MD1-M3G E2E-X4MD2-M3G Unshielded Note: In addition to the above models, E2E-X@D15-M1G models (e.g., E2E-X3D15-M1G), which are different in frequency from the above models, are available. DC 2-wire/Pre-wired Connector Models Size Shielded Sensing distance M12 3 mm M18 7 mm M30 Unshielded Operation mode Polarity NO 10 mm Model Yes E2E-X3D1-M1GJ No E2E-X3D1-M1J-T Yes E2E-X7D1-M1GJ No E2E-X7D1-M1J-T Yes E2E-X10D1-M1GJ No E2E-X10D1-M1J-T Yes E2E-X8MD1-M1GJ M12 8 mm M18 14 mm E2E-X14MD1-M1GJ M30 20 mm E2E-X20MD1-M1GJ *1. A model with no polarity has a residual voltage of 5 V, which must be taken into consideration together with the interface condition (the PLC's ON voltage, for example) when connecting the Proximity Sensor to a load. *2. The standard cable length is 300 mm. Models are also available with 500 mm and 1 m cables. Connector Pin Assignments of DC 2-wire Model The connector pin assignments of each new E2E DC 2-wire conforms to IEC947-5-2 Table III. The following E2E models with conventional connector pin assignments are available as well. Size Shielded 2 Operation mode Model M8 NO E2E-X2D1-M1 NC E2E-X2D2-M1 M12 NO E2E-X3D1-M1 NC E2E-X3D2-M1 M18 NO E2E-X7D1-M1 NC E2E-X7D2-M1 M30 NO E2E-X10D1-M1 NC E2E-X10D2-M1 Size Unshielded Operation mode Model M8 NO E2E-X4MD1-M1 NC E2E-X4MD2-M1 M12 NO E2E-X8MD1-M1 NC E2E-X8MD2-M1 M18 NO E2E-X14MD1-M1 NC E2E-X14MD2-M1 M30 NO E2E-X20MD1-M1 NC E2E-X20MD2-M1 Inductive Sensors DC 3-wire/Pre-wired Models Size Shielded Sensing Output distance configuration M8 M12 M18 M30 Unshielded AC 2-wire/Pre-wired Models M8 M12 M18 M30 1.5 mm 2 mm 5 mm 10 mm 2 mm 5 mm 10 mm 18 mm NPN NO Model E2E-X1R5E1 (See notes 1 and 2.) NPN NC E2E-X1R5E2 PNP NO E2E-X1R5F1 PNP NC E2E-X1R5F2 NPN NO E2E-X2E1 (See notes 1, 2, 3, and 4.) NPN NC E2E-X2E2 (See notes 3 and 4.) PNP NO E2E-X2F1 PNP NC E2E-X2F2 NPN NO E2E-X5E1 (See notes 1, 2, 3, and 4.) NPN NC E2E-X5E2 (See notes 3 and 4.) PNP NO E2E-X5F1 PNP NC E2E-X5F2 NPN NO E2E-X10E1 (See notes 1, 2, 3, and 4.) NPN NC E2E-X10E2 (See notes 3 and 4.) PNP NO E2E-X10F1 PNP NC E2E-X10F2 NPN NO E2E-X2ME1 (See note 2.) NPN NC E2E-X2ME2 PNP NO E2E-X2MF1 PNP NC E2E-X2MF2 NPN NO E2E-X5ME1 (See notes 1, 2, 3, and 4.) NPN NC E2E-X5ME2 (See notes 3 and 4.) PNP NO E2E-X5MF1 PNP NC E2E-X5MF2 NPN NO E2E-X10ME1 (See notes 1, 2, 3, and 4.) NPN NC E2E-X10ME2 (see notes 3 and 4.) PNP NO E2E-X10MF1 PNP NC E2E-X10MF2 NPN NO E2E-X18ME1 (See notes 1, 2, 3, and 4.) NPN NC E2E-X18ME2 (See notes 3 and 4.) PNP NO E2E-X18MF1 PNP NC E2E-X18MF2 Size Shielded Unshielded Sensing distance M8 1.5 mm Operation mode NO Model E2E-X1R5Y1 NC E2E-X1R5Y2 E2E-X2Y1 (See notes 1 and 2.) M12 2 mm NO NC E2E-X2Y2 M18 5 mm NO E2E-X5Y1 (See notes 1 and 2.) NC E2E-X5Y2 M30 10 mm NO E2E-X10Y1 (See notes 1 and 2.) NC E2E-X10Y2 M8 2 mm NO E2E-X2MY1 NC E2E-X2MY2 M12 5 mm NO E2E-X5MY1 (See notes 1 and 2.) NC E2E-X5MY2 M18 10 mm NO E2E-X10MY1 (See note 1.) NC E2E-X10MY2 M30 18 mm NO E2E-X18MY1 (See note 1.) NC E2E-X18MY2 Note: 1. Models with a different frequency are also available. These models are E2E-X@Y@5 (e.g., E2E-X5Y15). 2. Cables with a length of 5 m are also available. Specify the cable length at the end of the model number (e.g., E2E-X2Y1 5M). Note: 1. Cables with a length of 5 m are also available. Specify the cable length at the end of the model number (e.g., E2E-X2E1 5M). 2. Models with a robotics cable are also available. These models are E2E-X@E1-R (e.g., E2E-X5E1-R). 3. Models with a different frequency are also available. These models are E2E-X@E@5 (e.g., E2E-X5E15). 4. These models have e-CON connectors (0.3 m cable length), which is indicated by the suffix "-ECON" (e.g., E2E-X2E1-ECON). E2E 3 DC 3-wire/Connector Models Connector M12 Size Shielded AC/DC 2-wire/Pre-wired Models Sensing Output distance configuration M8 1.5 mm M12 2 mm M18 5 mm M30 10 mm Unshielded M8 2 mm M12 5 mm M18 10 mm M30 18 mm M8 Shielded M8 Unshielded M8 1.5 mm 2 mm Model NPN NO E2E-X1R5E1-M1 NPN NC E2E-X1R5E2-M1 PNP NO E2E-X1R5F1-M1 PNP NC E2E-X1R5F2-M1 NPN NO E2E-X2E1-M1 NPN NC E2E-X2E2-M1 PNP NO E2E-X2F1-M1 PNP NC E2E-X2F2-M1 NPN NO E2E-X5E1-M1 NPN NC E2E-X5E2-M1 PNP NO E2E-X5F1-M1 PNP NC E2E-X5F2-M1 NPN NO E2E-X10E1-M1 NPN NC E2E-X10E2-M1 PNP NO E2E-X10F1-M1 PNP NC E2E-X10F2-M1 NPN NO E2E-X2ME1-M1 NPN NC E2E-X2ME2-M1 PNP NO E2E-X2MF1-M1 PNP NC E2E-X2MF2-M1 NPN NO E2E-X5ME1-M1 NPN NC E2E-X5ME2-M1 PNP NO E2E-X5MF1-M1 PNP NC E2E-X5MF2-M1 NPN NO E2E-X10ME1M1 NPN NC E2E-X10ME2M1 PNP NO E2E-X10MF1-M1 PNP NC E2E-X10MF2-M1 NPN NO E2E-X18ME1M1 NPN NC E2E-X18ME2M1 PNP NO E2E-X18MF1-M1 PNP NC E2E-X18MF2-M1 NPN NO E2E-X1R5E1-M3 NPN NC E2E-X1R5E2-M3 PNP NO E2E-X1R5F1-M3 PNP NC E2E-X1R5F2-M3 NPN NO E2E-X2ME1-M3 NPN NC E2E-X2ME2-M3 PNP NO E2E-X2MF1-M3 PNP NC E2E-X2MF2-M3 Size Shielded Sensing distance Operation mode NO Model M12 3 mm M18 7 mm E2E-X7T1 (See note 2.) E2E-X3T1 M30 10 mm E2E-X10T1 *1. These models do not conform to CE standards. *2. Cables with a length of 5 m are also available as standard models. Specify the cable length at the end of the model number (e.g., E2E-X7T1 5M). AC 2-wire/Connector Models Size Shielded Sensing distance M12 M18 M30 Unshielded M12 M18 M30 4 2 mm 5 mm 10 mm 5 mm 10 mm 18 mm Operation mode Model NO E2E-X2Y1-M1 NC E2E-X2Y2-M1 NO E2E-X5Y1-M1 NC E2E-X5Y2-M1 NO E2E-X10Y1-M1 NC E2E-X10Y2-M1 NO E2E-X5MY1-M1 NC E2E-X5MY2-M1 NO E2E-X10MY1-M1 NC E2E-X10MY2-M1 NO E2E-X18MY1-M1 NC E2E-X18MY2-M1 Inductive Sensors Specifications Ratings/Characteristics E2E E2E-X@D@ DC 2-wire Models Size Type Item Sensing distance Set distance (See note 1.) Differential travel Sensing object Standard sensing object Response speed (See note 2.) Power supply voltage (operating voltage range) Leakage current Control Load curoutput rent Residual voltage (See note 3.) Indicator Operation mode (with sensing object approaching) Diagnostic output delay Protection circuits Ambient temperature Ambient humidity Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Weight Pre-wired (packed models state) Pre-wired connector models Connector models Material Case Sensing surface Cable Clamping nuts Toothed washer Accessories M8 Shielded E2E-X2D@ 2 mm 10% 0 to 1.6 mm Unshielded E2E-X4MD@ 4 mm 10% 0 to 3.2 mm Shielded E2E-X3D@ M12 Unshielded E2E-X8MD@ 3 mm 10% 0 to 2.4 mm 8 mm 10% 0 to 6.4 mm M18 Unshielded E2EX14MD@ 7 mm 10% 14 mm 10% 0 to 5.6 mm 0 to 11.2 mm Shielded E2E-X7D@ M30 Shielded Unshielded E2E-X10D@ E2EX20MD@ 10 mm 10% 20 mm 10% 0 to 8.0 mm 0 to 16.0 mm 15% max. of sensing distance 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.) Iron, 8 x 8 x Iron, 20 x 20 x Iron,12 x 12 x Iron,30 x 30 x Iron, 18 x 18 x Iron, 30 x 30 x Iron,30 x 30 x 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm 1.5 kHz 1.0 kHz 1.0 kHz 0.8 kHz 0.5 kHz 0.4 kHz 0.4 kHz Iron, 54 x 54 x 1 mm 0.1 kHz 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. 0.8 mA max. 3 to 100 mA Diagnostic output: 50 mA for -D1(5)S models 3 V max. (Load current: 100 mA, Cable length: 2 m. M1J-T models only: 5 V max.) D1 Models: Operation indicator (red LED), setting indicator (green LED) D2 Models: Operation indicator (red LED) D1 Models: NO D2 Models: NC For details, refer to Timing Charts. 0.3 to 1 s Surge suppressor, output load short-circuit protection (for control and diagnostic output) Operating: -25 C to 70 C, Storage: -40 C to 85 C (with no icing or condensation) Operating/Storage: 35% to 95% (with no condensation) 15% max. of sensing dis10% max. of sensing distance at 23 C in the temperature range of -25 C to 70 C tance at 23 C in the temperature range of -25 C to 70 C 1% max. of sensing distance in the rated voltage range 15% 50 M min. (at 500 VDC) between current-carrying parts and case 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions 500 m/s2 10 times each in X, 1,000 m/s2 10 times each in X, Y, and Z directions Y, and Z directions IEC 60529 IP67 (Pre-wired models, pre-wired connector models: JEM standard IP67g (waterproof and oil-proof)) Pre-wired models (standard length: 2 m), connector models, pre-wired connector models (standard length: 0.3 m) Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g --- Approx. 40 g Approx. 70 g Approx. 110 g Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g Stainless steel (SUS303) Brass-nickel plated PBT (polybutylene terephthalate) PVC (polyvinyl chloride) all E2E-@@@-U PUR/PE (polyurethane/polyethylene) Brass-nickel plated Iron-zinc plated Instruction manual Note: 1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 models). 2. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 3. The residual voltage of each E2E model with the model number suffix "-M1J-T" is 5 V. When connecting an E2E model with the suffix "-M1J-T" to a device, make sure that the device can withstand the residual voltage. E2E 5 E2E-X@E@/F@ DC 3-wire Models M8 Size Type Item Shielded M12 Unshielded E2E-X1R5E@/ E2E-X2ME@/ F@ F@ M18 M30 Shielded Unshielded Shielded Unshielded Shielded Unshielded E2E-X2E@/ F@ E2E-X5ME@/ F@ E2E-X5E@/ F@ E2E-X10ME@/ F@ E2E-X10E@/ F@ E2E-X18ME@/ F@ Sensing distance 1.5 mm 10% 2 mm 10% 2 mm 10% 5 mm 10% 5 mm 10% 10 mm 10% 10 mm 10% 18 mm 10% Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 1.6 mm 0 to 4.0 mm 0 to 4.0 mm 0 to 8.0 mm 0 to 8.0 mm 0 to 14.0 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.) Standard sensing object Iron, 8 x 8 x 1 mm Iron, 12 x 12 x Iron, 12 x 12 x Iron, 15 x 15 x Iron, 18 x 18 x Iron, 30 x 30 x Iron, 30 x 30 x Iron, 54 x 54 x 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm Response speed (See note 1.) 2.0 kHz 0.8 kHz Power supply voltage (operating voltage range) (See note 2.) 12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max. Current consumption 13 mA max. Control output 1.5 kHz 0.4 kHz 0.6 kHz 0.2 kHz 0.4 kHz 0.1 kHz Load current 200 mA max. (See note 2.) Residual voltage Indicator 2 V max. (Load current : 200 mA, Cable length: 2 m) Operation indicator (red LED) Operation mode E1 F1 Models: NO (with sensing object ap- E2 F2 Models: NC proaching) For details, refer to Timing Charts. Protection circuits Power supply reverse polarity protection, surge suppressor, output load short-circuit protection Ambient temperature (See note 2) Operating/Storage: -40 C to 85 C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95% (with no icing) Temperature influence 15% max. of sensing distance at 23 C in the temperature range of -40 C to 85 C 10% max. of sensing distance at 23 C in the temperature range of -25 C to 70 C Voltage influence 1% max. of sensing distance in the rated voltage range 15% Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance 500 m/s2 10 times each in X, Y, 1,000 m/s2 10 times each in X, Y, and Z directions and Z directions Degree of protection IEC 60529 IP67 (Pre-wired models: JEM standard IP67g (waterproof and oil-proof)) Connection method Pre-wired models (standard length 2 m), connector models Weight (packed state) Pre-wired models Approx. 65 g Approx. 75 g Approx. 150 g Approx. 195 g Connector models Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g Material Case Stainless steel (SUS303) Brass-nickel plated Sensing sur- PBT (polybutylene terephthalate) face Cable PVC (polyvinyl chloride) Clamping nuts Brass-nickel plated Toothed washer Iron-zinc plated Accessories Instruction manual Note: 1. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2. When using an E2E with an M8 connector at an ambient temperature range between 70 C and 85 C, supply 10 to 30 VDC to the E2E and make sure that the E2E has a control output of 100 mA maximum. 6 Inductive Sensors E2E-X@Y@ AC 2-wire Models M8 Size Type Item M12 Unshielded Shielded E2E-X1R5Y@ E2E-X2MY@ M18 Shielded Unshielded Shielded Unshielded E2E-X2Y@ E2E-X5MY@ E2E-X5Y@ E2E-X10MY@ M30 Shielded Unshielded E2E-X10Y@ E2E-X18MY@ Sensing distance 1.5 mm 10% 2 mm 10% 2 mm 10% 5 mm 10% 5 mm 10% 10 mm 10% 10 mm 10% 18 mm 10% Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4.0 mm 0 to 4.0 mm 0 to 8.0 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.) Standard sensing object Iron, 8 x 8 x 1 mm Response speed 25 Hz Power supply voltage (operating voltage range) (See note 1.) 24 to 240 VAC, 50/60 Hz (20 to 264 VAC) Leakage current 1.7 mA max. Control Load curoutput rent (See note 2.) 5 to 100 mA Residual voltage Indicator 0 to 1.6 mm 0 to 8.0 mm 0 to 14.0 mm Iron,12 x 12 x Iron, 12 x 12 x Iron, 15 x 15 x Iron, 18 x 18 x Iron, 30 x 30 x Iron, 30 x 30 x Iron, 54 x 54 x 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm 5 to 200 mA 5 to 300 mA Refer to Engineering Data. Operation indicator (red LED) Y1 Models: NO Operation mode (with sensing object Y2 Models: NC For details, refer to Timing Charts. approaching) Protection circuit Surge suppressor Ambient temperature Operating/Storage: -25 C to Operating/Storage: -40 C to 85 C (with no icing or condensation) (See notes 1 and 2.) 70 C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95% (with no condensation) Temperature influence 15% max. of sensing distance at 23 C in the temperature range of -40 C to 85 C 10% max. of sensing distance at 23 C in the temper- 10% max. of sensing distance at 23 C in the temperature range of -25 C to 70 C ature range of -25 C to 70 C Voltage influence 1% max. of sensing distance in the rated voltage range 15% Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 4,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case (2,000 VAC for M8 Models) Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance 500 m/s2 10 times each in X, 1,000 m/s2 10 times each in X, Y, and Z directions Y, and Z directions Degree of protection IEC 60529 IP67 (Pre-wired models: JEM standard IP67g (waterproof, oil-proof)) Connection method Pre-wired models (standard length 2 m), connector models Weight Pre-wired (packed models state) Connector models Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g Material Case Stainless steel (SUS303) Brass-nickel plated Sensing surface PBT (polybutylene terephthalate) Cable PVC (polyvinyl chloride) Clamping nuts Brass-nickel plated Toothed washer Iron-zinc plated Accessories Instruction manual Note: 1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is over -25 C. 2. When using an M18-or M30-sized E2E within an ambient temperature of 70 C to 85 C, make sure that the E2E has a control output of 5 to 200 mA max. E2E 7 AC/DC 2-wire Models Size M12 M18 Type M30 Shielded Item E2E-X3T1 E2E-X7T1 E2E-X10T1 Sensing distance 3 mm 10% 7 mm 10% 10 mm 10% Set distance 0 to 2.4 mm 0 to 5.6 mm 0 to 8.0 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.) Standard sensing object Iron, 12 x 12 x 1 mm Iron, 18 x 18 x 1 mm Iron, 30 x 30 x 1 mm Response speed (See note 1.) DC 1.0 kHz 0.5 kHz 0.4 kHz AC 25 Hz Power supply voltage 24 to 240 VDC (20 to 264 VDC)/48 to 240 VAC (40 to 264 VAC) (operating voltage range) (See note 2.) Leakage current Control output 1 mA DC max., 2 mA AC max. Load current 5 to 100 mA Residual voltage 6.0 VDC max. (Load current: 100 mA, Cable length: 2 m) 10 VAC max. (Load current: 5 mA , Cable length: 2 m) Indicator Operation indicator (red LED), setting indicator (green LED) Operation mode (with sensing object approaching) NO For details, refer to Timing Charts. Protection circuits Output load short-circuit protection (at 20 to 40 VDC), Surge suppressor Ambient temperature Operating: -25 C to 70 C, Storage: -40 C to 85 C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95% (with no condensation) Temperature influence 10% max. of sensing distance at 23 C in the temperature range of -25 C to 70 C Voltage influence 1% max. of sensing distance in the rated voltage range 15% Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 4,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC 60529 IP67 (JEM standard IP67g (waterproof, oil-proof)) Connection method Pre-wired Models (standard length 2 m) Weight (packed state) Material Approx. 80 g Case Approx. 140 g Approx. 190 g Brass-nickel plated Sensing surface PBT (polybutylene terephthalate) Cable PVC (polyvinyl chloride) Clamping nuts Brass-nickel plated Toothed washer Iron-zinc plated Accessories Instruction manual Note: 1. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2. Power supply voltage waveform: Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset. 8 Inductive Sensors Engineering Data E2E Operating Range (Typical) Shielded Models E2E-X@D@ E2E-X@T1 E2E-X@E@/F@ E2E-X@Y@ 8 E2E-X7 6 E2E-X3 E2E-X2 Y 4 X 2 -15 -10 -5 0 5 E2E-X10 10 Y 8 X 6 E2E-X5 E2E-X2 4 E2E -X1R5 2 1.4 Y X 1.2 E2E-X1/E2E-C1 1.0 0.8 E2E-CR8 0.6 0.4 0.2 0 -15 10 15 20 DistanceY (mm) Sensing distance X (mm) E2E-X10 10 0 -20 1.6 12 Sensing distance X (mm) Sensing distance X (mm) 12 E2E-C@C@/B@ E2E-X@C@/B@ -10 -5 0 5 0 -3.0 10 15 Distance Y (mm) -2.0 -1.0 0 1.0 2.0 3.0 Distance Y (mm) Unshielded Models E2E-X@MD@ E2E-X@ME@/F@ E2E-X@MY@ 30 30 20 E2E-X20M 15 10 E2E-X14M Y X E2E-X8M 5 0 -30 Sensing distance X (mm) Sensing distance X (mm) Y 25 E2E-X4M -20 -10 0 X 25 20 E2E-X18M 15 E2E-X10M 10 E2E-X5M E2E-X2M 5 0 -30 10 20 30 Distance Y (mm) -20 -10 0 10 20 30 Distance Y (mm) Leakage Current (Typical) E2E-X@Y@ E2E-X2D1-N E2E-X7D1-N Supply voltage (V) E2E E2E-X@T1 DC/AC AC power supply Proximity Sensor (when OFF) Protective resistance AC power supply Supply voltage (V) Leakage current (mA) E2E-X10D1-N E2E-X3D1-N Leakage current (mA) Leakage current (mA) E2E-X@D@ DC power supply Supply voltage (V) 9 Residual Output Voltage (Typical) E2E-X@T1 E2E-X@D@ 200 VAC 4 E2E-X@D1-M1J-T 3 E2E-X@D@ 2 1 0 1 3 5 10 30 50 Residual output voltage (V) Residual output voltage (V) 5 100 VAC 24 VDC 100 Load current (mA) Load current (mA) E2E-X@Y@ 24 VAC 100 VAC 200 VAC Residual output voltage Proximity Sensor 24 VAC OFF Load current (mA) Proximity Sensor 100 VAC Residual load voltage OFF Load current (mA) Load voltage VL (V) Residual output voltage Residual load voltage 10 Load voltage VL (V) Load voltage VL (V) Residual output voltage Proximity Sensor 200 VAC Residual load voltage OFF Load current (mA) Inductive Sensors Sensing Distance vs. Sensing Object (Typical) E2E-X2D@ E2E-X3D@ E2E-X3T1 E2E-X7D@ E2E-X7T1 t = 1 mm Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) Iron Stainless steel (SUS304) Brass Aluminum Copper Iron Sensing distance (mm) Iron Sensing distance (mm) Sensing distance (mm) t = 1 mm Side length of sensing object d (mm) E2E-X10D@ E2E-X10T1 Stainless steel (SUS304) t = 1 mm Side length of sensing object d (mm) E2E-X4MD@ E2E-X8MD@ Copper t = 1 mm Side length of sensing object d (mm) E2E-X14MD@ t = 1 mm Iron Stainless steel (SUS304) Brass Aluminum Copper Sensing distance (mm) Sensing distance (mm) Stainless steel (SUS304) Brass Aluminum Sensing distance (mm) t = 1 mm Iron Side length of sensing object d (mm) E2E-X20MD@ Stainless steel (SUS304) Brass Aluminum Copper E2E-X1R5E@/F@ E2E-X1R5Y@ t = 1 mm Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) Iron Stainless steel (SUS304) Brass Aluminum Copper t = 1 mm Side length of sensing object d (mm) Sensing distance (mm) Iron Sensing distance (mm) Sensing distance (mm) Iron Side length of sensing object d (mm) t = 1 mm E2E Brass Aluminum Copper Iron Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) 11 E2E-X2E@/F@ E2E-X2Y@ E2E-X5E@/F@ E2E-X5Y@ E2E-X10E@F@ E2E-X10Y@ t = 1 mm Brass Iron Stainless steel (SUS304) Brass Aluminum Aluminum Side length of sensing object d (mm) Side length of sensing object d (mm) Stainless steel (SUS304) Brass t = 1 mm Aluminum Side length of sensing object d (mm) E2E-X5ME@/F@ E2E-X5MY@ E2E-X2ME@/F@ E2E-X2MY@ Iron Sensing distance (mm) Stainless steel (SUS304) Sensing distance (mm) Sensing distance (mm) t = 1 mm Iron E2E-X10ME@/F@ E2E-X10MY Stainless steel (SUS304) Brass Aluminum t = 1 mm Copper Iron Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) Side length of sensing object d (mm) Sensing distance (mm) Sensing distance (mm) Iron Sensing distance (mm) t = 1 mm Iron Stainless steel (SUS304) Brass t = 1 mm Aluminum Side length of sensing object d (mm) E2E-X1@@ E2E-X18ME@/F@ E2E-X18MY@ Iron Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) 12 Sensing distance (mm) Sensing distance (mm) t = 1 mm Iron Stainless steel (SUS304) Brass Aluminum t = 1 mm Side length of sensing object d (mm) Inductive Sensors Output Circuits and Timing Charts Output Circuits E2E E2E-X@D@ DC 2-wire Models E2E-X@D1 Without Diagnostic Output E2E-X@D1-M1J-T No Polarity 1 4 Load Brown Proximity sensor main circuit E2E-X@D1S With Diagnostic Output Proximity sensor main circuit 4 Load Load (0 V) Load Proximity sensor main circuit 3 Blue 4 Brown Orange (diagnostic output) 2 0V 0V Blue 3 Note: 1. The load can be connected to Note: 1. The load can be connected to either the +V or 0 V side. either the +V or 0 V side. 2. The pin numbers in the above diagram 2. The E2E-X@D1-M1J-T has no are for the -M@G(J). For the -M1, pin 4 polarity. Therefore, terminals 3 is +V and pin 3 is 0 V. and 4 have no polarity. 0V Note: Connect both the loads to the +V side of the control output and diagnostic output. E2E-X@D2 Without Diagnostic Output 1 Load Brown Proximity sensor main circuit 2 Blue 0V Note: 1. The load can be connected to either the +V or 0 V side. 2. The pin numbers in the above diagram are for the -M@G. For -M1 models, pin 2 is +V and pin 3 is 0 V. DC 3-wire Models E2E-X@E@ NPN Output E2E-X@F@ PNP Output Brown 1 Brown 1 100 Proximity sensor main circuit ** Constant current* Proximity sensor main circuit Load Black 4 (or 2)** Blue 3 Black 4 (or 2)*** Load * 100 * Constant current output is 1.5 to 3 mA. ** Pin 4 is an NO contact, and pin 2 is an NC contact. E2E-C/X@C@ NPN Open-collector Output 0V Blue 3 0V * Constant current output is 1.5 to 3 mA. ** When connecting to a Tr circuit. *** Pin 4 is an NO contact, and pin 2 is an NC contact. E2E-C/X@B@ PNP Open-collector Output Brown 1 Brown 1 100 Load Proximity sensor main circuit Proximity sensor main circuit Black 4 Output Black 4 Load Blue 3 E2E 0V 100 Blue 3 0V 13 E2E-X@Y@ AC 2-wire Models Brown 3 (or 1) Load Proximity sensor main circuit Blue 4 (or 2) Note: For connector models, the connection between pins 3 and 4 uses an NO contact, and the connection between pins 1 and 2 uses an NC contact. E2E-X@T1 AC/DC 2-wire Models Brown Load Proximity sensor main circuit 24 to 240 VDC 48 to 240 VAC Power supply Blue Note: The load can be connected to either the +V or 0 V side. There is no need to be concerned about the polarity (Brown/Blue) of the Proximity Sensor. 14 Inductive Sensors Timing Charts E2E E2E-X@D@ DC 2-wire Models E2E-X@T1 AC/DC 2-wire Models E2E-X@D1 E2E-X@T1 NO Models E2E-X@D2 NC Models Set position Unstable Stable sensing sensing area area Non-sensing area Proximity Sensor Sensing object Non-sensing area Sensing area Proximity Sensor ON OFF ON OFF ON OFF Setting indicator (green) Rated sensing distance Rated sensing distance Sensing object Operation indicator (red) ON Control output ON OFF OFF Operation indicator (red) Control output E2E-X@D1S Non-sensing area Set position Unstable Stable sensing sensing area area Proximity Sensor Rated sensing distance Sensing object ON OFF ON OFF ON OFF ON OFF Setting indicator (green) Operation indicator (red) Note: The diagnostic output of the E2E-X@D1S is ON when there is a coil burnout or the sensing object is located in the unstable sensing range for 0.3 s or more. Control output Diagnostic output (see note) DC 3-wire Models E2E-X@E@ NPN Output E2E-X@F@ PNP Output Sensing object Yes No ON Operation indicator (red) OFF ON Control output between brown and black lines OFF H Output voltage L between black and blue lines Sensing Yes object No Operation ON indicator (red) OFF Control output ON between black and blue lines OFF Output voltage ON between black and blue lines OFF E2E-C/X@C@/B@ NPN/PNP Open-collector Output Yes No Operation ON indicator (red) OFF Sensing object Control output ON OFF E2E-X@Y@ AC 2-wire Models Yes No Operation ON indicator (red) OFF Sensing object Control output E2E ON OFF 15 Installation Connection E2E E2E-X@D@ DC 2-wire Models (Without Diagnostic Output) E2E-X@D1S DC 3-wire Models (With Diagnostic Output) E2E-X@D1-M1J-T DC 2-wire Models (No Polarity) E2E-X@Y@ AC 2-wire Models E2E-X@Y@ AC 2-wire Models Brown E2E-X@T1 AC/DC 2-wire Models Brown Orange Load Blue Load Brown Load Power supply Note: The control output and diagnostic output share the negative common terminal. Therefore, the loads must be connected to the positive sides of the control output and diagnostic output. Blue Brown Power supply Blue E2E-X@T1 AC/DC 2-wire Models Load Power supply Blue Note: There is no need to be concerned about the polarity (Brown/Blue) of the Proximity Sensor. Load Note: The load can be connected as shown above. Connected to PC E2E-X@D@ DC 2-wire Models E2E-X@E@ DC 3-wire Models Brown Brown Black Blue Blue 24 VDC 24 VDC Connected to Relay Load E2E-X@D@ DC 2-wire Models E2E-X@E@ DC 3-wire Models Brown 24 VDC Blue 16 E2E-X@F@ DC 3-wire Models Brown Brown Black Black Blue Blue Inductive Sensors Pin Arrangement E2E-X@D@-M@ DC 2-wire Models Connector SelfOperadiagnostic tion output mode M12 No NO Applicable models E2E-X@D1-M1G@ Pin arrangement Load E2E-X@-D1M1TGJ@U Load (See note.) Note: Terminals 2 and 3 are not used. E2E-X@D1-M1J-T Load or or Load Note: 1. Terminals 1 and 2 are not used. 2. Terminals 3 and 4 has no polarity. E2E-X@D1-M1 Load Load Note: Terminals 1 and 2 are not used. NC E2E-X@D2-M1G Load E2E-X@-D2M1TGJ@U (See note.) Load Note: Terminals 3 and 4 are not used. E2E-X@D2-M1 Load Load Note: Terminal 1 is not used. Yes NO E2E-X@D1S-M1 (Self-diagnostic output) Load Load M8 No NO Note: Terminals 1 is not used. E2E-X@D1-M3G Load Load Note: Terminals 2 and 3 are not used. NC E2E-X@D2-M3G Load Load Note: Terminals 3 and 4 are not used. Note: The above pin arrangements conform to IEC standards. E2E 17 E2E-X@E/F@-M@ DC 3-wire Models Connector M12 Operation mode NO Applicable models Pin arrangement E2E-X@E1-M1 Load Note: Terminal 2 is not used. Load Note: Terminal 2 is not used. E2E-X@F1-M1 NC E2E-X@E2-M1 Load Note: Terminal 4 is not used. E2E-X@F2-M1 Note: Terminal 4 is not used. Load M8 NO E2E-X@E1-M3 Note: Terminal 2 is not used. Load E2E-X@F1-M3 Note: Terminal 2 is not used. Load NC E2E-X@E2-M3 Note: Terminal 4 is not used. Load E2E-X@F2-M3 Note: Terminal 4 is not used. Load 18 Inductive Sensors E2E-CR8C@/CR8B@/X1C@/X1B@-M5 DC 3-wire Models Connector M8-3pin Operation mode Applicable models NO/NC Pin arrangement E2E-X1C@-M5 DC 4 1 3 Load NO/NC E2E-X1B@-M5 DC 4 1 3 Load E2E-X@Y@-M1 AC 2-wire Models Operation mode NO Applicable models Pin arrangement E2E-X@Y1-M1 Load Load Note: Terminals 1 and 2 are not used. NC E2E-X@Y2-M1 Load Load Note: Terminals 3 and 4 are not used. E2E 19 Precautions Mounting Model Do not tighten the nut with excessive force. A washer must be used with the nut. M8 Shielded Model Unshielded Model Shielded 9 mm Unshielded 3 mm Part B Torque Torque 9 N*m M12 30 N*m M18 70 N*m M30 180 N*m 12 N*m Influence of Surrounding Metal When mounting the E2E within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the sensor. Part B Part A Part B Part A Part A Length Note: The table below shows the tightening torques for part A and part B nuts. In the previous examples, the nut is on the sensor head side (part B) and hence the tightening torque for part B applies. If this nut is in part A, the tightening torque for part A applies instead. d dia. Model E2E-X@D@ DC 2-wire Shielded E2E-X@T1 AC/DC 2-wire Unshielded E2E-X@E@ E2E-X@F@ DC 3-wire Shielded E2E-X@Y@ AC 2-wire DC 3-wire Unshielded E2E2-X@Y@ AC 2-wire Item M8 M12 M18 M30 l 0 mm 0 mm 0 mm 0 mm d 8 mm 12 mm 18 mm 30 mm D 0 mm 0 mm 0 mm 0 mm m 4.5 mm 8 mm 20 mm 40 mm n 12 mm 18 mm 27 mm 45 mm l 12 mm 15 mm 22 mm 30 mm d 24 mm 40 mm 70 mm 90 mm D 12 mm 15 mm 22 mm 30 mm m 8 mm 20 mm 40 mm 70 mm n 24 mm 40 mm 70 mm 90 mm l 0 mm 0 mm 0 mm 0 mm d 8 mm 12 mm 18 mm 30 mm D 0 mm 0 mm 0 mm 0 mm m 4.5 mm 8 mm 20 mm 40 mm n 12 mm 18 mm 27 mm 45 mm l 6 mm 15 mm 22 mm 30 mm d 24 mm 40 mm 55 mm 90 mm D 6 mm 15 mm 22 mm 30 mm m 8 mm 20 mm 40 mm 70 mm n 24 mm 36 mm 54 mm 90 mm Relationship between Sizes and Models E2E Model Model M8 M12 M18 20 Model No. Shielded E2E-X2D@ E2E-X1R5E@/F@ E2E-X1R5Y@ Unshielded E2E-X4MD@ E2E-X2ME@/F@ E2E-X2MY@ Shielded E2E-X3D@ E2E-X2E@/F@ E2E-X2Y@ E2E-X3T1 Unshielded E2E-X8MD@ E2E-X5ME@/F@ E2E-X5MY@ Shielded E2E-X7D@ E2E-X5E@/F@ E2E-X5Y@ E2E-X7T1 Unshielded E2E-X14MD@ E2E-X10ME@/F@ E2E-X10MY@ M30 Model No. Shielded E2E-X10D@ E2E-X10E@/F@ E2E-X10Y@ E2E-X10T1 Unshielded E2E-X20MD@ E2E-X18ME@/F@ E2E-X18MY@ Inductive Sensors Mutual Interference When installing two or more Sensors face to face or side by side, ensure that the minimum distances given in the following table are maintained. B A Model Item E2E-X@D@ DC 2-wire Shielded E2E-X@T1 AC/DC 2-wire Unshielded E2E-X@E@ E2E-X@F@ DC 3-wire Shielded E2E-X@Y@ AC 2-wire Unshielded M12 M18 A 20 mm M8 30 (20) mm 50 (30) mm 100 (50) mm M30 B 15 mm 20 (12) mm 35 (18) mm 70 (35) mm A 80 mm 120 (60) mm 200 (100) mm 300 (100) mm B 60 mm 100 (50) mm 110 (60) mm 200 (100) mm A 20 mm 30 (20) mm 50 (30) mm 100 (50) mm B 15 mm 20 (12) mm 35 (18) mm 70 (35) mm A 80 mm 120 (60) mm 200 (100) mm 300 (100) mm B 60 mm 100 (50) mm 110 (60) mm 200 (100) mm WARNING This product is not designed or rated for ensuring safety of persons. Do not use it for such purposes. Precautions for Safe Use The colors in parentheses are previous wire colors. Item Power supply Do not impose an excessive voltage on the E2E, otherwise it may explode or burn. Do not impose 100 VAC on any E2E DC Model, otherwise it may explode or burn. Examples DC 3-wire Models DC 2-wire Models Brown Brown Sensor Incorrect Black Do not short-circuit the load, or the E2E may explode or burn. The E2E short-circuit protection function is valid if the polarity of the supply voltage imposed is correct and within the rated voltage range. Incorrect Sensor Blue Load short-circuit Load Load Blue DC 3-wire Models (NPN output) Brown Load (Load shortcircuit) Sensor Black Blue Incorrect DC 2-wire Models The following diagram shows that the load is short-circuited while the polarity of the supply voltage imposed on the E2E/E2E2 is wrong, in which case the E2E/E2E2 may explode or burn. Load Brown (Load short-circuit) Incorrect Sensor Blue Wiring Be sure to wire the E2E and load correctly, otherwise it may explode or burn. DC 3-wire Models (NPN output) Load Brown Brown Sensor Load Incorrect Black Make sure to connect a proper load to the E2E in operation, otherwise it may explode or burn. DC 3-wire Models Brown AC 2-wire Models Load Load Brown Sensor Sensor Blue Blue Incorrect E2E Incorrect Blue Black Blue Connection with no load Sensor Incorrect 21 Precautions for Correct Use Installation Cable Tractive Force Power Reset Time Do not pull on cables with tractive forces exceeding the following. The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Diameter Tractive force 4 dia. max. 30 N max. 4 dia. min. 50 N max. Power OFF Mounting The Proximity Sensor may output a pulse signal when it is turned OFF. Therefore, it is recommended to turn OFF the load before turning OFF the Proximity Sensor. The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water-resistivity. Power Supply Transformer Environment When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Water Resistivity Sensing Object Metal Coating: The sensing distances of the Proximity Sensor vary with the metal coating on sensing objects. Wiring High-tension Lines Wiring through Metal Conduit If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. The Proximity Sensors are tested intensively on water resistance, but in order to ensure maximum performance and life expectancy avoid immersion in water and provide protection from rain or snow. Operating Enviroment Ensure the usage of the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Connecting Load to AC/DC 2-wire Sensor Refer to the following before using AC or DC 2-wire Proximity Sensors. Surge Protection Although the Proximity Sensor has a surge absorption circuit, if there is any machine that has a large surge current (e.g., a motor or welding machine) near the Proximity Sensor, connect a surge absorber to the machine. Leakage Current When the Proximity Sensor is OFF, the Proximity Sensor has leakage current. Refer to page 9 Leakage Current Characteristics. In this case, the load is imposed with a small voltage and the load may not be reset. Before using the Proximity Sensor, make sure that this voltage is less than the load reset voltage. The AC 2-wire Proximity Sensor cannot be connected to any card-lift-off relay (e.g., the G2A) because contact vibration of the relay will be caused by the leakage current and the life of the relay will be shortened. Loads with Large Inrush Currents (E2E-X@T@) Connecting a load that has a large inrush current (e.g., a lamp or motor) may result in a malfunction due to the inrush current causing a load short-circuit. Countermeasures Against Leakage Current AC 2-wire Models Connect a bleeder resistor as the bypass for the leakage current so that the current flowing into the load will be less than the load reset current. As shown in the following diagram, connect the bleeder resistor so that the current flowing into the Proximity Sensor will be 10 mA minimum and the residual voltage imposed on the load will be less than the load reset voltage. Load Bleeder resistor R VAC power supply VS P: The allowable power of the bleeder resistor. (The actual power capacity of the bleeder resistor must be at least a few times as large as the allowable power of the bleeder resistor.) I: Load current (mA) The following resistors are recommended. 100 VAC (supply voltage): A resistor with a resistance of 10 k maximum and an allowable power of 3 W minimum 200 VAC (supply voltage): A resistor with a resistance of 20 k maximum and an allowable power of 10 W minimum If these resistors generate excessive heat, use a resistor with a resistance of 10 k maximum and an allowable power of 5 W minimum at 100 VAC and a resistor with a resistance of 20 k maximum and an allowable power of 10 W minimum at 200 VAC instead. DC 2-wire Models Connect a bleeder resistor as the bypass for the leakage current so that the current flowing into the load will be less than the load reset current. Load Bleeder resistor R Refer to the following to calculate the bleeder resistance and the allowable power of the bleeder resistor. R VS/(iR - iOFF) (k) P > VS2/R (mW) P: The allowable power of the bleeder resistor. (The actual power capacity of the bleeder resistor must be at least a few times as large as the allowable power of the bleeder resistor.) iR: Leakage current of Sensors (mA) iOFF: Release current of load (mA) The following resistors are recommended. 12 VDC (supply voltage): A resistor with a resistance of 15 k maximum and an allowable power of 450 mW minimum 24 VDC (supply voltage): A resistor with a resistance of 30 k maximum and an allowable power of 0.1 W minimum Refer to the following to calculate the bleeder resistance and the allowable power of the bleeder resistor. R VS/(10 - I) (k) P > VS2/R (mW) 22 Inductive Sensors Connection to a PLC Example Required Conditions In this example, the above conditions are checked for when the PLC model is the C200H-ID212, the Proximity Sensor model is the E2EX7D1-N, and the power supply voltage is 24 V. Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following conditions. (The meanings of the symbols are given below.) 1. VON (14.4 V) VCC (20.4 V) - VR (3 V) = 17.4 V: OK 2. IOFF (1.3 mA) Ileak (0.8 mA): OK 1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following. VON VCC - VR 2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following. IOFF Ileak (If the OFF current is not listed in the specifications, take it to be 1.3 mA.) 3. The ON current of the PLC and the control output (IOUT) of the Proximity Sensor must satisfy the following. IOUT(min) ION IOUT(max) The ON current of the PLC will vary, however, with the power supply voltage and the input impedance used as shown in the following equation. ION = (VCC - VR - VPC )/RIN 3. ION = [VCC (20.4 V) - VR (3 V) - VPC (4 V)]/RIN (3 k) 4.5 mA Therefore, IOUT(min) (3 mA) ION (4.5 mA): OK VON: ON voltage of PLC (14.4 V) ION: ON current of PLC (typ. 7 mA) IOFF: OFF current of PLC (1.3 mA) RIN: Input impedance of PLC (3 k) VPC: Internal residual voltage of PLC (4 V) VR: Output residual voltage of Proximity Sensor (3 V) Ileak: Leakage current of Proximity Sensor (0.8 mA) IOUT: Control output of Proximity Sensor (3 to 100 mA) VCC: Power supply voltage (PLC: 20.4 to 26.4 V) Values in parentheses are for the following PLC model and Proximity Sensor model. PLC: C200H-ID212 Proximity Sensor: E2E-X7D1-N Precautions for AC/DC 2-wire Proximity Sensors in Operation Connection Model DC 2-wire Connection type AND (serial connection) Method Description The Sensors connected together must satisfy the following conditions. Correct VS - N x VR Load operating voltage N: No. of Sensors VR: Residual voltage of each Sensor VS: Supply voltage Load If each Proximity Sensor is not supplied with the rated voltage and current, the indicator will not be lit properly or unnecessary pulses may be output for approximately 1 ms. OR (parallel connection) The Sensors connected together must satisfy the following conditions. Correct Load N x i Load reset current N: No. of Sensors i: Leakage current of each Sensor If the MY Relay, which operates at 24 VDC, is used as a load for example, a maximum of four Proximity Sensors can be connected to the load. AC 2-wire AND (serial connection) If 100 or 200 VAC is imposed on the Proximity Sensors, VL (i.e., the voltage imposed on the load) will be obtained from the following. Incorrect Load VL = VS - (residual voltage x No. of Proximity Sensors) (V) Therefore, if VL is lower than the load operating voltage, the load will not operate. Correct A maximum of three Proximity Sensors can be connected in series provided that the supply voltage is 100 V minimum. Load Load Vs x 100 V E2E 23 Model Connection type AC 2-wire OR (parallel connection) Method Description In principle, more than two Proximity Sensors cannot be connected in parallel. Incorrect A Load Provided that Proximity Sensor A does not operate with Proximity Sensor B simultaneously and there is no need to keep the load operating continuously, the Proximity Sensors can be connected in parallel. In this case, however, due to the total leakage current of the Proximity Sensors, the load may not reset properly. B Correct Load A B VAC power supply VS It is not possible to keep the load operating continuously with Proximity Sensors A and B in simultaneous operation to sense sensing objects due to the following reason. When Proximity Sensor A is ON, the voltage imposed on Proximity Sensor A will drop to approximately 10 V and the load current flows into Proximity Sensor A, and when one of the sensing objects is close to Proximity Sensor B, Proximity Sensor B will not operate because the voltage imposed on Proximity Sensor B is 10 V, which is too low. When Proximity Sensor A is OFF, the voltage imposed on Proximity Sensor B will reach the supply voltage and Proximity Sensor B will be ON. Then, Proximity Sensor A as well as Proximity Sensor B will be OFF for approximately 10 ms, which resets the load for an instant. To prevent the instantaneous resetting of the load, use a relay as shown on the left. DC 3-wire AND (serial connection) Correct Load The Sensors connected together must satisfy the following conditions. iL + (N -1) x i Upper-limit of control output of each Sensor VS - N x VR Load operating voltage N: No. of Sensors VR: Residual voltage of each Sensor VS: Supply voltage i: Current consumption of the Sensor iL: Load current If the MY Relay, which operates at 24 VDC, is used as a load for example, a maximum of two Proximity Sensors can be connected to the load. 24 Inductive Sensors Dimensions Note: All units are in millimeters unless otherwise indicated. E2E Model DC 2-wire Model No. Pre-wired Shielded Model No. AC 2-wire Figure No. Model No. AC/DC 2-wire Figure No. Model No. Figure No. M8 E2E-X2D@-N 4 E2E-X1R5E@/F@ 4 E2E-X1R5Y@ 6 M12 E2E-X3D@-N 8 E2E-X2E@/F@ 8 E2E-X2Y@ 10 E2E-X3T1 12 M18 E2E-X7D@-N 13 E2E-X5E@/F@ 13 E2E-X5Y@ 13 E2E-X7T1 13 M30 E2E-X10D@-N 15 E2E-X10E@/F@ 15 E2E-X10Y@ 15 E2E-X10T1 15 E2E-X4MD@ 5 E2E-X2ME@/F@ 5 E2E-X2MY@ 7 --- --- E2E-X8MD@ 9 E2E-X5ME@/F@ 9 E2E-X5MY@ 11 M18 E2E-X14MD@ 14 E2E-X10ME@/F@ 14 E2E-X10MY@ 14 M30 E2E-X20MD@ 16 E2E-X18ME@/F@ 16 E2E-X18MY@ 16 M8 E2E-X2D@-M1(G) 17 E2E-X1R5E@-M1/F@-M1 17 --- --- --- --- M12 E2E-X3D@-M1(G) 19 E2E-X2E@-M1/F@-M1 19 E2E-X2Y@-M1 21 M18 E2E-X7D@-M1(G) 23 E2E-X5E@-M1/F@-M1 23 E2E-X5Y@-M1 23 M30 E2E-X10D@-M1(G) 25 E2E-X10E@-M1/F@-M1 25 E2E-X10Y@-M1 25 Unshield- M8 ed M12 E2E-X4MD@-M1(G) 18 E2E-X2ME@-M1/F@-M1 18 --- --- --- --- E2E-X8MD@-M1(G) 20 E2E-X5ME@-M1/F@-M1 20 E2E-X5MY@-M1 22 M18 E2E-X14MD@-M1(G) 24 E2E-X10ME@-M1/F@-M1 24 E2E-X10MY@-M1 24 M30 E2E-X20MD@-M1(G) 26 E2E-X18ME@-M1/F@-M1 26 E2E-X18MY@-M1 26 M8 E2E-X2D@-M3G 27 E2E-X1R5E@-M3/F@-M3 27 --- --- --- --- E2E-X4MD@-M3G 28 E2E-X2ME@-M3/F@-M3 28 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- Unshield- M8 ed M12 Connector (M12) DC 3-wire Figure No. Shielded Connector (M8) Shielded Pre-wired connector Shielded Unshielded M8 E2E-X2D@-M1TGJ-U 29 M12 E2E-X3D1-M1GJ 30 E2E-X3D@-M1TGJ-U M18 E2E-X7D1-M1GJ 32 E2E-X7D@-M1TGJ-U M30 E2E-X10D1-M1GJ 34 E2E-X10D@-M1TGJ-U Unshield- M12 ed M18 Pre-wired connector (no polarity) Shielded E2E-X8MD1-M1GJ 31 E2E-X14MD1-M1GJ 33 M30 E2E-X20MD1-M1GJ 35 M12 E2E-X3D1-M1J-T 30 M18 E2E-X7D1-M1J-T 32 M30 E2E-X10D1-M1J-T 34 Note: 1. Two clamping nuts and one toothed washer are provided with M8 to M30 Models. 2. The model numbers of Pre-wired M8 to M30 Models are laser-marked on the milled section and cable section. E2E 25 Pre-wired Models (Shielded) Pre-wired Models (Unshielded) Fig. 4 : E2E-X2D@-N E2E-X1R5E@/F@ Fig. 5 : E2E-X4MD@ E2E-X2ME@/F@ 30 7 30 15 dia. 15 dia. 3 13 13 8 7 26 26 6 8 3 6.1 dia. Indicator (See note.) Two clamping nuts M8 x 1 Toothed washer 4-dia. round cable with 2 conductors (D Models)/3 conductors (E, F Models) (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m Robotics cable Models: 4-dia. vinyl-insulated round cable with 2 conductors (D Models)/3 conductors (E Models)(Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m The cable can be exteded up to 200 m (separate metal conduit). Note: D Models: Operation indicator (red), setting indicator (green); E, F Models: Operation indicator (red) Fig. 6 : E2E-X1R5Y@ 3 Fig. 7 : E2E-X2MY@ 40 15 dia. 36 13 4-dia. round cable with 2 conductors (D Models)/3 conductors (E, F Models) (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m Note: D Models: Operation indicator (red), Robotics cable models: 4-dia. setting indicator (green); vinyl-insulated round cable with E, F Models: Operation indicator (red) 2 conductors (D Models)/3 conductors (E Models)(Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m The cable can be exteded up to 200 m (separate metal conduit). 7 40 15 dia. Indicator (See note.) Two Toothed clamping nuts washer M8 x 1 13 8 7 36 6 8 3 6.1 dia. M8 x 1 Two clamping nuts Toothed washer Fig. 8 : E2E-X3D@-N E2E-X2E@/F@ Pre-wired e-CON connector Model 38 9 33 21 dia. 4 10 M8 x 1 4-dia. round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be exteded up to 200 m (separate metal conduit). 1 2 17 Operation indicator (red) Two clamping nuts Toothed washer Operation Indicator (red) 3 4 5.9 Fig. 9 : E2E-X8MD@ E2E-X5ME@/F@ 4-dia. round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be exteded up to 200 m (separate metal conduit). Pre-wired e-CON connector Model 1 2 38 15 15.6 Connector: Product code 37104-3163-000FL (Sumitomo 3M) 9 33 21 dia. 17 7 4 10 3 4 5.9 15 15.6 Connector: Product code 37104-3163-000FL (Sumitomo 3M) 9 dia. M12 x 1 Indicator (See note.) Two clamping nuts Toothed washer Note: D Models: Operation indicator (red), setting indicator (green); E, F Models: Operation indicator (red) 26 4-dia. round cable with 2 conductors (D Models)/3 conductors (D@S,E, F Models) (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m Robotics cable Models: 4-dia. vinyl-insulated round cable with 2 conductors (D Models)/3 conductors (E Models) (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m (control output) or up to 100 m (diagnostic output). M12 x 1 Indicator 4-dia. round cable with 2 conductors (See note.) (D Models)/3 conductors (D@S, E, F Models) Two (Conductor cross section: 0.3 mm2, clamping nuts Insulator diameter: 1.3 mm), Toothed Standard length: 2 m washer Robotics cable models: 4-dia. Note: D Models: Operation indicator (red), setting indicator (green); E, F Models: Operation indicator (red) vinyl-insulated round cable with 2 conductors (D Models)/3 conductors (E Models) (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m (control output) or up to 100 m (diagnostic output). Inductive Sensors Pre-wired Models (Shielded) Pre-wired Models (Unshielded) Fig. 10 : E2E-X2Y@ Fig. 11 : E2E-X5MY@ 43 43 9 17 4 17 10 9 38 21 dia. 38 21 dia. 7 10 4 9 dia. Two clamping nuts Toothed washer 4-dia. round cable with 2 conductors (Conductors cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). Two clamping nuts Toothed washer 4-dia. round cable with 2 conductors (Conductors cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). Fig. 12 : E2E-X3T1 60 Operation indicator (red) M12 x 1 Operation indicator (red) M12 x 1 9 55 21 dia. 17 4 10 M12 x 1 Two clamping nuts Toothed washer Indicator (See note.) 4-dia. cable with 2 conductors (Conductors cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). Note: Operation indicator (red), setting indicator (green) Fig. 13 : E2E-X7D@-N/ E2E-X5E@/F@ E2E-X5Y@/E2E-X7T1 Pre-wired e-CON connector Model 1 2 43 15.6 43 24 Two clamping nuts Toothed washer Note: D, T Models: Operation indicator (red), setting indicator (green); E, F, Y Models: Operation indicator (red) Fig. 15 : E2E-X10D@-N/ E2E-X10E@/F@ E2E-X10Y@/ E2E-X10T1 6-dia. round cable with 2 conductors (D, Y, T Models)/3 conductors (D@S, E, F Models) (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm) Standard length: 2 m Robotics cable models: 6-dia. vinyl-insulated round cable with 2 conductors (D Models)/ 3 conductors (E Models) (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm) Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m (control output) or up to 100 m (diagnostic output). Pre-wired e-CON connector Model 1 2 48 12 43 42 dia. 5 36 10 3 4 5.9 15.6 10 Toothed washer Note: D Models: Operation indicator (red), setting indicator (green); E, F, Y Models: Operation indicator (red) 6-dia. round cable with 2 conductors (D, Y, T Models)/3 conductors (D@S, E, F Models) (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm) Standard length: 2 m Robotics cable Models: 6-dia. vinylinsulated round cable with 2 conductors (D Models)/3 conductors (E Models) (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm) Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m (control output) or up to 100 m (diagnostic output). Fig. 16 : E2E-X20MD@/ E2E-X18ME@/F@ E2E-X18MY@ Pre-wired e-CON connector Model 1 2 15 15.6 Connector: Product code 37104-2206-000FL (Sumitomo 3M) 48 12 43 42 dia. 13 36 15 3 4 Connector: Product code 37104-2206-000FL (Sumitomo 3M) Indicator (See note.) Two clamping nuts M18 x 1 5.9 1 2 12 4 10 14.8 dia. Indicator (See note.) M18 x 1 Pre-wired e-CON connector Model 38 29 dia. Connector: Product code 37104-2206-000FL (Sumitomo 3M) 10 4 24 Fig. 14 : E2E-X14MD@/ E2E-X10ME@/F@ E2E-X10MY@ 15 3 4 12 38 29 dia. 5.9 5 10 3 5.9 15 4 15.6 Connector: Product code 37104-2206-000FL (Sumitomo 3M) 26.8 dia. 6-dia. round cable with 2 conductors 6-dia. round cable with 2 conductors M30 x 1.5 Indicator (See note.) (D, Y, T Models)/3 conductors Two clamping nuts Toothed washer Note: D, T Models: Operation indicator (red), setting indicator (green); E,F,Y Models: Operation indicator (red) E2E (D@S, E, F Models) (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m Robotics cable Models: 6-dia. vinylinsulated round cable with 2 conductors (D Models)/3 conductors (E Models) (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m (control output) or up to 100 m (diagnostic output). M30 x 1.5 Toothed washer Indicator (D, Y, T Models)/3 conductors (See note.) (D@S, E, F Models) Two (Conductor cross section: 0.5 mm2, clamping nuts Insulator diameter: 1.9 mm), Note: D Models: Operation indicator (red), setting indicator (green); E, F, Y Models: Operation indicator (red) Standard length: 2 m Robotics cable Models: 6-dia. vinylinsulated round cable with 2 conductors (D Models)/ 3 conductors (E Models) (Conductor cross section: 0.5 mm2, Insulator diameter: 1.74 mm), Standard length: 2 m The cable can be extended (separate metal conduit) up to 200 m (control output) or up to 100 m (diagnostic output). 27 M12 Connector Models (Shielded) M12 Connector Models (Unshielded) Fig. 17 : E2E-X2D@-M1(G) E2E-X1R5E@-M1/F@-M1 Fig. 18 : E2E-X4MD@-M1(G) E2E-X2ME@-M1/F@-M1 43 43 30 15 dia. 26 M12 x 1 8 3 13 30 15 dia. 26 M12 x 1 8 3 6 13 6.1 dia. Indicator (See note.) Two clamping nuts Toothed washre M8 x 1 Indicator (See note.) Two clamping nuts Toothed washer M8 x 1 Toothed washer Note: D Models: Operation indicator (red), setting indicator (green) E, F Model: Operation indicator (red) Fig. 19 : E2E-X3D@-M1(G) E2E-X2E@-M1/F@-M1 Note: D Models: Operation indicator (red), setting indicator (green) E, F Model: Operation indicator (red) Fig. 20 : E2E-X8MD@-M1(G) E2E-X5ME@-M1/F@-M1 48 48 4 17 33 21 dia. 33 21 dia. 10 7 17 M12 x 1 M12 x 1 10 4 9 dia. Indicator (See note.) Two clamping nuts Toothed washer M12 x 1 Note: D Models: Operation indicator (red), setting indicator (green) E, F Model: Operation indicator (red) Fig. 21 : E2E-X2Y@-M1 Indicator (See note.) Two clamping nuts Toothed washer M12 x 1 Note: D Models: Operation indicator (red), setting indicator (green) E, F Model: Operation indicator (red) Fig. 22 : E2E-X5MY@-M1 53 53 38 21 dia. 4 17 38 21 dia. 10 M12 x 1 7 17 M12 x 1 10 4 9 dia. M12 x 1 Operating indicator (red) Two clamping nuts Toothed washer Fig. 23 : E2E-X7D@-M1(G)/E2E-X5E@-M1/F@-M1 E2E-X5Y@-M1 Operation indicator (red) Two clamping nuts Toothed washer M12 x 1 Fig. 24 : E2E-X14MD@-M1(G)/E2E-X10ME@-M1/F@-M1 E2E-X10MY@-M1 53 53 38 29 dia. 4 24 38 29 dia. 10 10 24 10 4 M12 x 1 M12 x 1 14.8 dia. Indicator (See note.) M18 x 1 Indicator (See note.) M18 x 1 Two clamping nuts Toothed washer Note: D Models: Operation indicator (red), setting indicator (green) E, F, Y Model: Operation indicator (red) Fig. 25 : E2E-X10D@-M1(G)/E2E-X10E@-M1/F@-M1 E2E-X10Y@-M1 Two clamping nuts Toothed washer Note: D Models: Operation indicator (red), setting indicator (green) E, F, Y Model: Operation indicator (red) Fig. 26 : E2E-X20MD@-M1(G)/E2E-X18ME@-M1/F@-M1 E2E-X18MY@-M1 58 58 5 36 36 10 M12 x 1 Indicator (See note.) M30 x 1.5 Two clamping nuts Toothed washer Note: D Models: Operation indicator (red), setting indicator (green) E, F, Y Model: Operation indicator (red) 28 43 42 dia. 43 42 dia. 13 26.8 dia. M30 x 1.5 5 10 M12 x 1 Indicator (See note). Two clamping nuts Toothed washer Note: D Models: Operation indicator (red), setting indicator (green) E, F, Y Model: Operation indicator (red) Inductive Sensors M8 Connector Models (Shielded) M8 Connector Models (Unshielded) Fig. 27 : E2E-X2D@-M3G/E2E-X1R5E@-M3/F@-M3 Fig. 28 : E2E-X4MD@-M3G/E2E-X2ME@-M3/F@-M3 39 31 39 31 15 dia. 15 dia. 26 8 3 13 26 3 6 13 M8 x 1 M8 x 1 8 6.1 dia. M8 x 1 Note: M8 x 1 Indicator (See note.) Two clamping nuts Toothed washer D models: Operation indicator (red), setting indicator (green) E, F model: Operation indicator (red) Note: Indicator (See note.) Two clamping nuts Toothed washer D models: Operation indicator (red), setting indicator (green) E, F model: Operation indicator (red) Pre-wired M12 Connector Models Fig. 29 : E2E-X2D@-M1TGJ-U 26 3 13 XS5 connector Smart Click 8 Indicator (See note.) Two clamping nuts M8 x 1 Toothed washer Fig. 30: 7 30 15 dia. E2E-X3D1-M1GJ E2E-X3D1-M1J-T E2E-X3D@-M1TGJ-U 38 4-dia. round cable, Standard length: 0.3 m 9 33 21 dia. XS5 connector Smart Click M12 x 1 10 4 17 Operation Indicator (red), setting indicator (green) M12 x 1 4-dia. round cable, Standard length: 0.3 m Two clamping nuts Toothed washer Fig. 31: E2E-X8MD1-M1GJ 38 9 33 21 dia. 10 4 7 17 M12 x 1 9 dia. Operation indicator (red), setting indicator (green) Two clamping nuts Toothed washer M12 x 1 4-dia. round cable, Standard length: 0.3 m Fig. 32 : E2E-X7D1-M1GJ E2E-X7D1-M1J-T E2E-X7D@-M1TGJ-U 43 4 24 M18 x 1 E2E 12 38 29 dia. 10 Operation indicator (red), setting indicator (green) Two calmping nuts Toothed washer XS5 connector Smart Click M12 x 1 6-dia. round cable, Standard length: 0.3 m 29 Pre-wired M12 Connector Models Fig. 33 : E2E-X14MD1-M1GJ 43 12 38 29 dia. 10 4 10 24 M12 x 1 14.8 dia. Operation indicator (red), setting indicator (green) Two clamping nuts Toothed washer M18 x 1 6-dia. round cable, Standard length: 0.3 m Fig. 34 : E2E-X10D1-M1GJ E2E-X10D1-M1J-T E2E-X10D@-M1TGJ-U 48 12 43 42 dia. 36 10 5 XS5 connector Smart Click M12 x 1 Operation indicator (red), setting indicator (green) Two clamping nuts M30 x 1.5 6-dia. round cable, Standard length: 0.3 m Toothed washer Fig. 35 : E2E-X20MD1-M1GJ 48 12 43 42 dia. 13 36 5 10 M12 x 1 26.8 dia. M30 x 1.5 Operation indicator (red), setting indicator (green) two clamping nuts 6-dia. round cable, Standard length: 0.3 m Toothed washer Mounting Holes F Dimensions F (mm) M8 8.5+0.5/0 dia. M12 12.5+0.5/0 dia. M18 18.5+0.5/0 dia. M30 30.5+0.5/0 dia. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 30 Inductive Sensors Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies ("Omron"). Omron objects to any terms or conditions proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron's payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in "break down" situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to "forbidden" or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, "including" means "including without limitation"; and "Omron Companies" (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON'S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON ELECTRONICS LLC * THE AMERICAS HEADQUARTERS * Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 www.omron247.com OMRON ARGENTINA * SALES OFFICE Cono Sur * 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br OMRON CHILE * SALES OFFICE Santiago * 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV * HEAD OFFICE Apodaca, N.L. * 52.811.156.99.10 * 001.800.556.6766 * mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Cat. No. D058-E2-03-X 09/08 Note: Specifications are subject to change. (c) 2010 Omron Electronics LLC Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: E2E-X2D2-N 5M E2E-X10D2-N 5M